1. Functions and Features
(1) Large penetration depth to measure artificial cracks on the surface or 8mm deep from the surface (dimension: 0.1*2*30mm).
(2) Low standby power and high efficiency.
(3) Compact, light-weight, and CCFS-II can be equipped with light and portable probe (2kg).
(4) High sensitivity with clear crack indication on test block type A.
(5) It can tolerate a lift-off (thin paint, coating, etc.)
(6) No requirement of demagnetization.
(7) Can be used with magnetic viewing film to store crack indication for a long time.
2. Technical Data for two versions CCFS-II/CCFS-IV
Lift force: >7 kg for CCFS-II, >15 kg for CCFS-IV
Working current: 0.8A for CCFS-II, 0.3A for CCFS-IV
Digital MCU variable frequency: 3HZ,10HZ,20HZ for CCFS-II, 10HZ, 40HZ for CCFS-IV
Sensitivity: A-15/100
Charging time: 5 hours, work life: 6 hours
High magnetic permeability probe (fillet weld probe, horseshoe-shaped probe optional for CCFS-II )
Power supply: 8.8AH lithium battery
Weight: Power source generator 1.7kg, yoke 2.1kg for CCFS-II / Power source generator 1.7kg, probe 2.3kg for CCFS-IV
Customizable camera for CCFS-Ⅳ.
LED white light and UV light of CCFS-Ⅳ can switch between each other.